
搜索
以空白搜尋找到 804 個結果
- 404 | 成都前宏
请检查您的链接是否正确或联系我司人员 回到前宏主页
- GP01-H62, Qianhong Communication
产品详情 全部 通信 终端和服务器 Telecommunication GP01-H62 In-Line Horizontal Fiber Optic Splice Closure The product is suitable for outdoor fiber optic cable overhead, pipeline and other straight-through splicing and divergence and other trunk fiber optic cable and common fiber optic cable network splicing. The use of double-ended horizontal design structure, with box internal residual fiber inventory space, can be placed directly fusion fiber bracket structure; The product has a high strength mechanical performance, high sealing performance, corrosion resistance, excellent weather resistance, etc., multi-cable port management, can be mechanically repeated to open; reasonable structure layout, simple and quick construction operation. Application Scenario Outdoor overhead, pipeline, direct buried and other common fiber optic cable joint splicing, can be used for metropolitan area network backbone, urban or urban and rural common fiber optic network splicing protection. Structure picture Performance characteristics 1、The shell is produced by injection molding process of high-quality engineering plastics, with anti-UV and anti-aging additives, high mechanical strength; 2、The box adopts double-ended optical cable in and out design structure, convenient overhead hanging rod and other openable structure; 3、the box body box cover using non-vulcanized rubber sealing structure, good airtightness; 4、Box with electrical disconnection or connection function, optional air nozzle; 5、high-capacity splicing, to meet the trunk or special fiber optic cable splicing protection; 7、termite resistance, acid and alkali resistant oil, resistance to extreme cold and high temperature environment need to order separate instructions. Technical parameters or parameters table 1、Adapted to the ambient temperature: -40℃~+70℃. 2、Atmospheric pressure: 70~106Kpa. 3、Axial tension: 〉1000N/1min or more. 4、flattening: the box is filled with 60 ± 5kpa air pressure, should be able to withstand 2000N/100mm lateral uniform pressure, the force time is not less than 1min, after the test joint box does not leak, no deformation, no damage. 5、 impact: fiber optic splice box should be able to withstand a drop height of 1m, the mass of the steel ball 1.6Kg, the number of impacts for 3 times the impact. 6、bending: fiber optic splice box and fiber optic cable joints should be able to withstand bending tension load of 150N, bending angle ± 45 ° of 10 cycles of bending. 7、torsion: fiber optic splice box should be able to withstand a torque of not less than 50N-m, torsion angle ± 90 °, a total of 10 cycles of twisting. 8、Drop: The fiber optic cable connector box should be able to withstand 3 drops at a height of 2.2m, and after the test, the connector box should not leak, no deformation, no damage. 9、tensile strength: 〉2000N/10cm2 pressure, time 1min. 10、vibration: splice box to withstand vibration frequency of 10Hz, amplitude of ± 3mm, the number of vibration for 106 vibration, the fiber additional loss change value does not exceed 0.2dB. 11、Temperature cycle: -40℃~+70℃, internal air pressure 60(+5)Kpa, 10 times cycle, air pressure drop not more than 5kpa after room temperature. 12、fiber radius of curvature > 37.5mm, fiber fusion tray additional attenuation ≤ 0.01dB. Commonly used tools for construction cross cutter, tape measure, hexagonal wrench. 点击下载产品手册 相关产品 主图1.jpg 主图2.jpg 主图7.jpg 主图1.jpg 1/7 In-Line Horizontal Fiber Optic Splice Closure GP01-H63 主图1.jpg 主图2.jpg 主图8.jpg 主图1.jpg 1/8 In-Line Horizontal Fiber Optic Splice Closure GP01-H61 主图1.jpg 主图2.jpg 主图7jpg.jpg 主图1.jpg 1/7 In-Line Horizontal Fiber Optic Splice Closure GP01-H60 主图1.jpg 主图2.jpg 主图7.jpg 主图1.jpg 1/7 In-Line Horizontal Fiber Optic Splice Closure GP01-H55
- 404 | 成都前宏
请检查您的链接是否正确或联系我司人员 回到前宏主页
- Integrated Cabinet
Product Details All Telecommunication Terminal and Server Electric 上一个产品 下一个产品 Integrated Cabinet Integrated cabinet, also known as integrated assembly rack, can be fiber optic units, digital units, audio wiring modules and other units in one, according to the need for a variety of combinations, flexible and versatile, can meet a variety of different needs, so that the circuit, optical wiring, wiring and transfer of business changes for convenient, flexible. SDH equipment units, ODF units, DDF units and MDF modules can be installed in the integrated assembly rack. Used in integrated base station transmission network, it can optimize fiber and cable alignment, save space and engineering investment in server room. Product advantages (1) Compatibility: standard U and standard 19-inch installation size design, strong adaptability, can install a variety of equipment; (2) structure solid: high-strength sheet metal cabinet, the overall welded structure, solid and reliable, surface spraying treatment; (3) alignment convenience: can be up and down into the line, both sides can line, according to the need to configure vertical and horizontal management line ring, optical cable fixed with a special fixed device, assembled in the back of the cabinet; (4) Excellent ventilation rate: optional rear double door mesh structure, ventilation rate of 80%; (5) Expandability: removable side panel design, convenient and rack expansion. (6) Convenient assembly: whole assembly or on-site assembly, fast and efficient installation, rapid site coverage; (7) Standardization: international standard installation size, closed structure, universal and safe; (8) Customization: Customizable according to customer needs. Product type The height of the rack is mainly 1200mm, 1600mm, 1800mm, 2000mm, 2200mm several specifications, width recommended size: 600mm, 800mm, depth recommended size: 450mm, 600mm, 800mm; the following table mainly lists the height of 2000mm, 2200mm cabinet specifications, the rest can be customized according to demand The rest can be customized according to demand. Product usage (1) through the use of intelligent integrated cabinet, to achieve the detection of outdoor front-end utility, communication links, temperature and humidity, flooding, opening and closing doors and other dynamic loop detection, external equipment power supply and current/voltage detection, detection of peripheral business communication interfaces, etc.; (2) the establishment of multiple cabinets combined use, through the platform of the center's core switching equipment, core routing equipment, storage devices, servers, databases and key applications to detect. Application tools wire hitting knives, open-end wrenches, openers, fusion splicers This product is a combination of active and passive standard cabinet, can be configured with a wide range of equipment, can achieve a wide range of functions, when using the audio module need to hit the line knife, when using the ODF module need to use the fusion machine for fiber fusion, other ordinary equipment installation process can be used in the Qizi, copper wiring occasions need to use the 16-19 open-end wrench to operate Other common equipment installation process can be used, there are copper wiring occasions need to use 16-19 open-end wrench to operate. Frequently Asked Questions How do I choose a rack? Data center users have a variety of options for open racks and enclosed enclosures for mounting equipment and access panels, each with its own advantages and disadvantages. As with cable channels, there is no universal solution. With respect to width, the specification for servers, switches and patch panels is 19 〃; for carrier equipment and other equipment of greater width in the introduction room, the applicable specification is 23 〃. The optimum height is 7" and the maximum allowable height is 8". How is the cable managed? Racks can be easily equipped for spacious, easy-access vertical cable managers. Many cabinets do not have enough space to accommodate vertical cable managers. Often, the only space available is in narrow, vertical corners and gaps between adjacent cabinets, neither of which is easily accessible. Cable entry holes, cable manager cross-sectional area are to be given by calculation. A minimum height of 100 mm (4 〃) should be left between the rails and the door for the cable manager, regardless of whether a patch panel is installed in the cabinet. What do I need to pay attention to when choosing an integrated cabinet? (1) Size: The size of the integrated cabinet needs to be determined according to the usage scenario, quantity and server specifications. If the purchased cabinet is too big or too small, it will easily cause waste of space utilization in the computer room or cannot accommodate the equipment. (2) load-bearing: comprehensive cabinets need to carry the product density is increasingly answer, so need to meet a certain load-bearing capacity. Generally speaking, the load-bearing capacity of multi-desktop network cabinets is more than 500KG. (3) Protection performance: Integrated cabinets are usually made of steel, but there are still differences in protection ability and leakage protection. If the earthquake, fire and other disaster conditions can ensure that its equipment from damage, there are more advantages. (4) Heat emission: The equipment inside the integrated network cabinet will generate a lot of heat when it works, and the heat dissipation capability of the cabinet needs to be considered to ensure the stable operation of the equipment inside the cabinet. At the same time, you can also choose the cabinet with a fan, which can ensure the cooling effect of the equipment. (5) management performance: integrated cabinet needs to be equipped with the corresponding management system for remote and local management. Users can investigate, monitor and manage the equipment inside the cabinet through the network or terminal interface. 上一个产品 下一个产品
- 404 | 成都前宏
请检查您的链接是否正确或联系我司人员 回到前宏主页
- All-in-one fusion tray, Qianhong Communication
产品详情 全部 通信 终端和服务器 Telecommunication All-in-one fusion tray Sheet Metal Integrated fusion tray, also known as fiber optic fusion distribution tray, fusion distribution integrated tray, widely used in fiber optic distribution frame, cable transfer box, can complete the fusion of optical fiber, adapter installation and a small amount of pigtail shelter. Product Benefits (1) With 12 cores as a unit, pigtails and fiber bundles have their own coiled wire channels and are managed in layers to effectively protect the fiber from damage. (2) Three layers structure, the lower layer is the wiring tray, the middle is the fusion tray, the top is the cover, fusion, wiring integration, easy to operate. (3) The adapter is at a 30° oblique angle to the front of the splicing unit, which ensures the bending radius of curvature of the jumping fiber and avoids laser burns to the human eye. (4) A variety of fusion and wiring labels, convenient to do fusion and wiring records. (5) Modular design, the fusion fiber tray integrates fiber optic fusion splicing, tray storage and wiring, and each integrated fusion fiber tray can be withdrawn individually to meet the off-rack or on-rack operation. (6) Available for FC, SC and LC adapters and ribbon and bundle fiber. Product structure schematic Product Type Product use fusion splicing, wiring, pigtail shelter The all-in-one fusion tray enables fusion splicing of optical fibers, installation of adapters and a small amount of pigtail intake. Product application tools Fiber melting machine, OTDR tester, pen red light source, wire stripping pliers, power meter, anhydrous ethanol, fiber cutting knife, optical power meter. Frequently Asked Questions How to choose the product adapter type-FC or SC? Choose according to the type of adapters used with other matching equipment in the cabinet or rack. How can I tell whether to use a ribbon fiber or a bundle fiber? According to the fiber optic cable used to choose, ribbon fiber optic cable then choose ribbon pigtail, bundle fiber optic cable choose bundle pigtail. How can I tell if I need to use the left or right disc on site? According to the site cabinet / rack pigtail channel in the left side of the fusion fiber tray then use the left tray, in the right side of the fusion fiber tray then use the right tray. What is the difference between the left and right trays of the fusion fiber tray? When a person faces the fusion tray, the adapter facing the left hand side of the person is the left tray, and the adapter facing the right hand side of the person is the right tray. 点击下载产品手册 相关产品 1/2 Sheet Metal Traditional fiber optic cable transfer box 主图1.jpg 主图2.jpg 主图6.jpg 主图1.jpg 1/17 Sheet Metal Fiber optic cable termination box 1/2 Sheet Metal No-jump fiber optic cable transfer box 1/2 Sheet Metal Expanded capacity fiber optic cable transfer box
- 404 | 成都前宏
请检查您的链接是否正确或联系我司人员 回到前宏主页
- 404 | 成都前宏
请检查您的链接是否正确或联系我司人员 回到前宏主页
- 404 | 成都前宏
请检查您的链接是否正确或联系我司人员 回到前宏主页
- GJS03-M15BX-A14-144C(GP394), Qianhong Communication
产品详情 全部 通信 终端和服务器 Telecommunication GJS03-M15BX-A14-144C(GP394) Dome Fiber Optic Splice Closure, M 11-14 The product is suitable for outdoor fiber optic cable overhead, pipeline and other straight-through splicing and divergence splicing. This product has high strength mechanical properties, high sealing performance, corrosion resistance, excellent weather resistance, etc., multi-cable port management, can be mechanically repeated to open, high maintainability; reasonable structure layout, simple and fast construction operation. Application Scenario Outdoor overhead, pipeline and other common fiber optic cable splice splicing, can be used for urban or urban and rural common fiber optic network splicing protection. Structure picture Performance characteristics 1、The shell is produced by injection molding process of high-quality engineering plastics, with anti-UV and anti-aging additives, high mechanical strength; 2、The box body adopts the single end in and out of the optical cable design structure, easy to install overhead hanging rods and other barrels can be quickly opened for maintenance and repair; open the box body without tools; 3、the shell and the bottom with silicone rubber sealing ring, optical cable mouth using temperature-resistant heat-shrinkable tube sealing, good airtightness; 4、Box with electrical disconnection or connection function, optional air nozzle. Technical parameters or parameters table 1、Adapted to the ambient temperature: -20℃~+65℃. 2、Atmospheric pressure: 70~106Kpa. 3、Axial tension: 〉1000N/1min or more. 4、flattening: the box is filled with 40 ± 5kpa air pressure, should be able to withstand 2000N/100mm lateral uniform pressure, the force time is not less than 1min, after the test joint box does not leak, no deformation, no damage. 5、impact: fiber optic splice box should be able to withstand a drop height of 1m, the mass of the steel ball 1.6Kg, the number of impacts for 3 times the impact. 6、bending: fiber optic splice box and fiber optic cable joints should be able to withstand bending tension load of 150N, bending angle ± 45 ° of 10 cycles of bending. 7、torsion: fiber optic splice box should be able to withstand a torque of not less than 50N-m, torsion angle ± 90 °, a total of 10 cycles of twisting. 8、Drop: The fiber optic cable connector box should be able to withstand 3 drops at a height of 2.2m, and after the test, the connector box should not leak, no deformation, no damage. 9、tensile strength: 〉2000N/10cm2 pressure, time 1min. 10、vibration: splice box to withstand vibration frequency of 10Hz, amplitude of ± 3mm, the number of vibration for 106 vibration, the fiber additional loss change value does not exceed 0.2dB. 11、Temperature cycle: -20℃~+65℃, internal air pressure 40(+5)Kpa, 10 times cycle, air pressure drop not more than 5kpa after room temperature. 12、fiber radius of curvature > 30mm, fiber fusion tray additional attenuation ≤ 0.01dB. Commonly used tools for construction cross cutter, tape measure, sawyer, heat blower or spray gun. Parameter table Model: GJS03-M15BX-A14-144C (GP394) Box material: PP Adaptation of fiber optic cable diameter: elliptical hole: 10-20mm Small hole: 6-12mm Number of cable entry ports: 2+16 Maximum capacity of fusion fiber tray (core): 24 Maximum number of fusion cores (cores): 144 Fiber optic residual fiber intake device: No Sealing method: mechanical + heat shrink seal Fiber into the end type and number: -- Product use environment: overhead, pipeline, buried 点击下载产品手册 相关产品 主图1.jpg 主图2.jpg 主图5.jpg 主图1.jpg 1/5 Dome Fiber Optic Splice Closure, M 11-14 GJS03-M15BX-A14-144C-NABS02(GP394) 主图1.jpg 主图2.jpg 主图4.jpg 主图1.jpg 1/4 Dome Fiber Optic Splice Closure, M 11-14 GJS03-M15AX-A14-144C-NABS02(GP394) 主图1.jpg 主图2.jpg 主图4.jpg 主图1.jpg 1/4 Dome Fiber Optic Splice Closure, M 11-14 GJS03-M15AX-A14-144C(GP394) 主图1.jpg 主图2.jpg 主图6.jpg 主图1.jpg 1/6 Dome Fiber Optic Splice Closure, M 11-14 GJS03-M14AX-JX-144C(GP374)